Search results for "pattern standard deviation"

showing 5 items of 5 documents

Multichannel functional testing in normal subjects, glaucoma suspects, and glaucoma patients

2012

Purpose.: To evaluate visual function with a novel multichannel functional test named the ATD Multichannel Functional Test. Methods.: This multicenter study had a prospective and cross-sectional design. A total of 186 eyes were included: 42 with glaucoma, 14 glaucoma suspects due to optic nerve characteristics, 25 ocular hypertensives, and 105 normal eyes. All patients performed standard visual fields (Humphrey 24-2) and ATD with eight stimuli configurations: four achromatic (A), two red-green (T), and two blue-yellow (D). To derive main outcome measures, mean sensitivity, mean defect (MD), and pattern standard deviation (PSD) were calculated and compared among groups and types of stimuli w…

AdultMalemedicine.medical_specialty61genetic structuresFunctional testingGlaucomaAudiologyCycles per degreeContrast SensitivityPattern standard deviationOjos--EnfermedadesReference ValuesOphthalmologyOptic Nerve Diseases617MedicineHumansProspective StudiesIntraocular PressureAgedbusiness.industryVision TestsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseNormal limiteye diseasesOphthalmologymedicine.anatomical_structureCross-Sectional StudiesMulticenter studyOftalmologiaEye--DiseasesOptic nerveOftalmologíaFemaleOcular Hypertensionsense organsVisual FieldsbusinessUlls--MalaltiesColor PerceptionOptic disc
researchProduct

Learning Curve and Fatigue Effect of Flicker Defined Form Perimetry

2011

To evaluate the learning curve and fatigue effect of flicker defined form (FDF) perimetry.Prospective cross-sectional study.One hundred forty-one eyes of 75 healthy subjects were included in the study. Every subject was measured 3 times on 3 different days within 3 months. Differences among the tests were analyzed for mean sensitivity (MS), mean deviation (MD), pattern standard deviation (PSD), reliability indices, test duration, and test points5% and0.5% in 75 right eyes on the basis of linear mixed models for repeated measurements. To assess the effect of fatigue, differences of MS, MD, and PSD values between 66 left and right eyes were evaluated regarding alterations between these 3 exam…

Adultmedicine.medical_specialtyVisual AcuitySignificant learningSensitivity and SpecificityPattern standard deviationOphthalmologymedicineHumansProspective StudiesIntraocular PressureAgedbusiness.industryFlickerHealthy subjectsGlaucomaMiddle AgedTest durationAbsolute deviationOphthalmologyCross-Sectional StudiesVisual Field TestsAsthenopiaVisual FieldsbusinessLearning CurveAmerican Journal of Ophthalmology
researchProduct

Deep Learning Estimation of 10-2 and 24-2 Visual Field Metrics Based on Thickness Maps from Macula OCT.

2021

Purpose To develop deep learning (DL) systems estimating visual function from macula-centered spectral-domain (SD) OCT images. Design Evaluation of a diagnostic technology. Participants A total of 2408 10-2 visual field (VF) SD OCT pairs and 2999 24-2 VF SD OCT pairs collected from 645 healthy and glaucoma subjects (1222 eyes). Methods Deep learning models were trained on thickness maps from Spectralis macula SD OCT to estimate 10-2 and 24-2 VF mean deviation (MD) and pattern standard deviation (PSD). Individual and combined DL models were trained using thickness data from 6 layers (retinal nerve fiber layer [RNFL], ganglion cell layer [GCL], inner plexiform layer [IPL], ganglion cell-IPL […

MaleDesign evaluationGlaucoma03 medical and health sciences0302 clinical medicinePattern standard deviationDeep LearningLinear regressionDiagnostic technologyMedicineHumansMacula LuteaIntraocular Pressure030304 developmental biologyAged0303 health sciencesbusiness.industryOutcome measuresGlaucomaMiddle Agedmedicine.diseaseConfidence intervalVisual fieldOphthalmologyBenchmarkingCross-Sectional Studies030221 ophthalmology & optometryFemaleVisual FieldsbusinessNuclear medicineTomography Optical CoherenceFollow-Up StudiesOphthalmology
researchProduct

The Heidelberg retina tomograph ancillary study to the European glaucoma prevention study: study design and baseline factors.

2013

Purpose: To describe the study design and baseline factors of the Heidelberg Retina Tomograph ancillary study within the EGPS. Furthermore, to examine the relationship between HRT optic disc topographic measurements and baseline demographic and ocular factors. Methods: Four hundred and eighty-nine ocular hypertensive participants were included. Each participant completed HRT imaging at least annually. The associations between HRT measurements and IOP, central corneal thickness (CCT), baseline photographic estimates of vertical CDR ratio (CDR), asymmetry between the two eyes in CDR ratio and baseline visual field indices were assessed using regression analysis. Results: Associations between …

MaleIntraocular pressureVisual acuitygenetic structuresOptic diskVisual AcuityOcular hypertensionGlaucomaOptic Nerve DiseasesMedicineHRT parameterCarbonic Anhydrase Inhibitorspattern standard deviationTomographySulfonamidesmedicine.diagnostic_testGeneral MedicineMiddle Agedmedicine.anatomical_structureResearch DesignOptic nerveFemalemedicine.symptomHumanOptic discmedicine.medical_specialtyCarbonic Anhydrase Inhibitorscanning laser ophthalmoscopyOptic DiskVisual FieldThiophenesSulfonamideOphthalmoscopyTonometry OcularOptic Nerve DiseaseDouble-Blind MethodThiopheneOphthalmologymental disordersHumansIntraocular Pressurebusiness.industryGlaucomamedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyOcular Hypertensionsense organsVisual Fieldsbusinesscentral corneal thickneActa ophthalmologica
researchProduct

Effect of Multizone Refractive Multifocal Contact Lenses on Standard Automated Perimetry

2012

PURPOSE The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). METHODS In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, an…

Malemedicine.medical_specialtygenetic structuresContact LensesOpticsCLs upper limitsPattern standard deviationOphthalmologymedicineHumansMathematicsCross-Over Studiesbusiness.industryAutomated perimetryPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseRefractive lensCrossover studyeye diseasesVisual fieldAbsolute deviationOphthalmologySensory ThresholdsVisual Field TestsFemaleVisual FieldsbusinessAlgorithmsEye &amp; Contact Lens: Science &amp; Clinical Practice
researchProduct